3701-31-04 (B)(6)(t) / Equipment/chemical/storage areas are free of hazards/accessible only to authorized personnel.
Critical Equipment/chemical/storage areas were not secured.
-Observed the main door in the hallway to the equipment room was not locked. Tenants have laundry facilities and apartments on this floor. A sign was posted that it was for employees only, but the door is not secured.
-The equipment room is a shared space with dumpsters and water heaters and other equipment, and the operator noted that the fire department does not allow the door to be locked.
-Discussed creating a cage around the equipment and chemcials.
These storage areas must be kept inaccessible to everyone but authorized personnel. Secure the areas.
3701-31-04 (D)(8)(c) / Test kit reagents fresh/ properly stored.
Test kit reagents were not fresh or stored properly.
-Observed expired reagents in the test kit.
REPLACE ANY EXPIRED REAGENTS.
Obtain fresh reagents and store them properly.
3701-31-04 (E)(2)(d) / First aid kit provided
Corrected During Inspection First aid equipment was not provided.
-Observed there was no first aid kit available at the pool.
-The operator obtained the test kit and brought it out to the pool.
Provide first aid equipment, including a first aid kit, at the pool at all times.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 07-July-2023
Comments |
---|
Our records show that the main drain suction outlet covers (A & A Channel )were installed 10/18/13. The covers have a 10 year life span and must be replaced before 10/18/2023. Discussed the requirements for test kits. Test strips are not to be used, because they are not a "DPD" test. Per OAC 3701-31-04-(D)(8): (a) The disinfection tests shall measure the free chlorine residual, the total or the combined chlorine residual or the bromine residual of a public swimming pool, with a test that uses diethyl l-p-phenylenediamine (DPD). (b) If water quality results cannot be obtained by a standard DPD test kit, the licensor may require the more specific FAS-DPD test. (c) Test kit reagents shall be fresh, properly stored to prevent degradation and used in accordance with the manufacturer's specifications. |