[?] A summary of the violations found during the inspection are listed below.

3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
Repeat ORP reading was below 650 mv
Have the ACC unit inspected to determined why the ORP is low. Correct By: 25-Sep-2018
3701-31-04 (B)(3) / Staff is trained and knowledgeable
Staff was not trained or knowledgeable in pool operations.
Train staff in pool operations, operation of equipment, chemical storage, use and handling and appropriate emergency procedures. Correct By: 25-Sep-2018
3701-31-04 (B)(4) / The licensee /authorized representative is keeping records
The licensee /authorized representative was not keeping or maintaining operational records.
All facility records must be maintained and available for review upon request. Check Chlorine/bromine, and pH once every 12 hours of operation, temperature daily, alkalinity weekly, and the ACC function switch and SVRS function monthly. Correct By: 19-Sep-2018
3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Required flow meters was not functional while the pool is in operation.
Repair the flow meter. Correct By: 25-Sep-2018
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Repeat pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range. Correct By: 25-Sep-2018
3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Emergency phone does not have emergency numbers posted by it.
Post emergency numbers by the phone. Correct By: 19-Sep-2018


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 18-September-2018