3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications. Weir missing in the skimmer.
All equipment must be maintained in accordance with the manufacturers specifications.
REPLACE THE MISSING WEIR IN THE SKIMMER. Correct By: 05-Aug-2022
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Corrected During Inspection Equipment was not maintained per manufacturers specifications. Flow rate exceeded filter maximum flow rate.
All equipment must be maintained in accordance with the manufacturers specifications.
REDUCE FLOW RATE TO 48 GPM OR LESS. Correct By: 29-Jul-2022
3701-31-04 (D)(7)(d) / Flow or pressure switch with a shut off valve shall be provided and tested monthly.
Critical Repeat Corrected During Inspection Flow or pressure switch for a shut off valve was not tested monthly
Provide records indicating that the unit is being tested monthly.
TEST AND RECORD THE AUTOMATIC CHEMICAL CONTROLLER FLOW SWITCH AT LEAST MONTHLY. Correct By: 29-Jul-2022
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 29-July-2022
Comments |
---|
RECOMMENDATIONS: -MAINTAIN 2-3 PPM FREE CHLORINE LEVEL TO PROVIDE A MARGIN OF SAFETY. BELOW 1 PPM FREE CHORINE THE POOL MUST CLOSE UNTIL LEVEL IS 1 PPM OR HIGHER. -SHOCK POOL TO REDUCE COMBINE CHLORINE. INCREASE AIR CIRCULATION DURING SHOCK TREATMENT. -OBTAIN AND USE DPD-FAS TEST KIT REAGENTS FOR TESTING CHLORINE LEVELS. REAGENT R-0781, R-0780, R-0003. |