3701-31-04 (A) / Approval shall be obtained for any construction or alterations of a public swimming pool.
Public swimming pool was constructed, installed, or substantially altered without obtaining approval from the Ohio Department of Health (ODH).
Contact ODH to obtain approval for any construction/alterations before operating pool.
SUBMIT AN ERN TO ODH FOR THE REPLACEMENT OF THE PUMP. Old Pump Sta-Rite PE5D-181L .75 HP. New pump Pentair Intelliflo Correct By: 28-Mar-2022
3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical Chlorine disinfectant residual was less than 2 ppm for the spa
Do not operate the spa when the disinfectant residuals are less than what is required. Ensure the chlorine disinfectant residual is at 2 ppm or above prior to placing the spa back into operation.
OPERATOR CLOSED SPA AT THE TIME OF INSPECTION. CALL ME WHEN SPA IS READY TO REOPEN. 44-219-7158. Correct By: 21-Mar-2022
3701-31-04 (B)(4)(c) / SVRS/APSOS/ACC test results/ service records are maintained
Repeat SVRS/APSOS/ACC test results/ service records were not maintained.
The test results/service records for these devices must be kept on site for review. If the device has not been recently serviced, have the device tested immediately and provide documentation of the test results.
TEST AND RECORD THE ACC FLOW SWITCH AND THE SVRS MONTHLY. RECORD ON THE WEEKLY LOG SHEET. Correct By: 28-Mar-2022
3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Chemical containers were stored without labels identifying the contents.
Quat Disinfectant stored above the Alkalinity up bucket.
Label and properly store all chemical containers to avoid a chemical reaction or unnecessary exposure.
DO NOT STORE LIQUID CHEMICALS ABOUT POWDERED OR DRY CHEMICALS. Correct By: 21-Mar-2022
3701-31-04 (D)(7) / Public spa shall have a functional automatic chemical controller
Critical The automatic chemical controller for the spa was not functioning properly
Have the ACC unit serviced or replaced if not able to be repaired.
REPAIR ACC SO CHLORINE FEEDS PROPERLY. OPERATOR CLOSED SPA AT TIME OF INSPECTION. Correct By: 21-Mar-2022
Facility Type: Spa
[?] Inspection Type: Standard
Inspection Date: 21-March-2022