3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical The skimmer equalizer outlets were not covered with a VGB compliant cover.
EITHER PLUGGED THE SKIMMER EQUALIZER OUTLETS OR COVER WITH A VGB COMPLIANT COVER. Correct By: 17-Jun-2019
3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Required meters and gauges were not maintained or were not functional while the pool is in operation.
Maintain all meters and gauges in a properly functioning manner at all times while the pool is in operation.
REPAIR THE FLOW METER. Correct By: 17-Jun-2019
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Repeat Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm.
ADJUST ALKALINITY Correct By: 17-Jun-2019
3701-31-04 (D)(7)(d) / Flow or pressure switch with a shut off valve shall be provided and tested monthly.
Critical Repeat Flow or pressure switch for a shut off valve was not provided or the unit was not tested monthly
Have the ACC unit serviced or replaced with a unit that has a flow or pressure switch with an automatic shut off valve. Provide records indicating that the unit is being tested monthly.
TEST THE AUTOMATIC CHEMICAL CONTROLLER FLOW SWITCH MONTHLY AND RECORD.
3701-31-04 (E)(2)(a)(ii) / A USCG Type IV personal flotation device with 30 -60 foot throw line provided
A USCG Type IV personal flotation device with 30 -60 foot throw line was not provided at the unguarded pool.
Provide a proper floatation device at all times.
TIE A 30-60 FT ROPE ONTO THE RING BUOY. Correct By: 17-Jun-2019
3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Emergency device (telephone) was not working.
Ensure that the emergency device is functioning properly and rings to the emergency response authorities.
REPAIR THE EMERGENCY PHONE. Correct By: 17-Jun-2019
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 13-June-2019
Comments |
---|
Our records have been updated to show: The main drain suction outlet cover (Lawson MLD-FGD-1212) was installed on 5-5-19. The cover has a 10 year life span and must be replaced before 5-5-29. -Clean the pump room -When recording the chlorine levels: free chlorine (FC) + combine chlorine (CC) = Total chlorine (TC) |