3701-31-04 (B)(4)(a)(vii) / Cyanuric acid is tested weekly
Cyanuric acid was not tested weekly.
Test for cyanuric acid level at least once/week.
TEST AND RECORD CYA ON THE WEEKLY LOG SHEET WEEKLY. Correct By: 10-Jul-2021
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. Flow meter not installed per instructions.
All equipment must be maintained in accordance with the manufacturers specifications.
INSTALL FLOW METER PER INSTRUCTIONS Correct By: 10-Jul-2021
3701-31-04 (B)(6)(c) / Cross connection hazards shall be prevented.
Cross connection hazards were present. The back flow preventer is a ASSE 1015.
Remove all cross connection hazards from the pool area.
INSTALL AN ASSE 1013 BACKFLOW PREVENTER. Correct By: 10-Jul-2021
3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Repeat Required turnover rates were not met.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve.
INCREASE FLOW RATE TO AT LEAST 76 GPM. A NEW PUMP MAY BE NEEDED OR EXISTING ONE REPAIRED. Correct By: 09-May-2022
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
ADJUST THE pH Correct By: 10-Jul-2021
3701-31-04 (D)(05) / Cyanuric acid level shall not exceed 70 ppm.
Cyanuric acid level exceeded 70 ppm
Drain the pool at least halfway and fill with clean water. Monitor the amount of cyanuric acid being used and adjust accordingly.
REDUCE CYANURIC ACID. Correct By: 10-Jul-2021
3701-31-04 (E)(3)(b) / "Children must be supervised" or "Swimming alone is not recommended" signs posted
Repeat The unguarded pool was in use without the "Swimming alone is not recommended" signs posted.
Post the "Swimming Alone is Not Recommended" signs at all times the pool is available for use.
POST REQUIRED SIGN. Correct By: 10-Jul-2021
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 08-July-2021