3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
ORP reading was below 650 mv
Have the ACC unit inspected to determined why the ORP is low. Correct By: 16-Jun-2023
3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical Outlet covers were not compliant covers. Covers are outdated and under sized.
Do not operate the pool without compliant outlet covers. Install compliant outlet covers prior to placing the pool back into operation.
INSTALL NEW MAIN DRAIN COVERS OF ADEQUATE FLOW RATING.
3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical Repeat Chlorine disinfectant residual was less than 1 ppm for the pool
Do not operate the pool when the disinfectant residuals are less than what is required. Ensure the chlorine disinfectant residual is at 1 ppm or above prior to placing the pool back into operation.
THIS IS A CRITICAL VIOLATION AND POSES AN IMMINENT HEALTH HAZARD. OPERATOR WAS INSTRUCTED TO TREAT THE POOL AND NOT LET SWIMMERS IN THE POOL UNTIL FREE CHLORINE LEVELS ARE AT LEAST 1 PPM. Correct By: 16-Jun-2023
3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Repeat Required meters and gauges were not maintained or were not functional while the pool is in operation.
Maintain all meters and gauges in a properly functioning manner at all times while the pool is in operation.
REPAIR FLOW METER.
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Repeat Ladders were not in good repair. Loose.
Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair.
TIGHTEN LADDERS Correct By: 22-Jun-2023
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Repeat pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
ADJUST pH Correct By: 17-Jun-2023
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 15-June-2023
Comments |
---|
Chemical feeder pumps should not be mounted above other chemical feeder pumps or chemical containers to prevent possible mixing of chemicals and producing toxic gas. If chlorine is mixed with muriatic acid chlorine gas is formed, which can lead to severe injuries and fatalities (SIFs) to exposed individuals. |