3701-31-04 (A) / Approval shall be obtained for any construction or alterations of a public swimming pool.
Repeat Public swimming pool was constructed, installed, or substantially altered without obtaining approval from the Ohio Department of Health (ODH).
Contact ODH to obtain approval for any construction/alterations before operating pool.
AN EQUIPMENT REPLACEMENT NOTIFICATION FORM MUST BE SUBMITTED TO THE OHIO DEPARTMENT OF HEALTH FOR THE REPLACEMENT OF THE DISINFECTION FEEDER AND THE FILTER. A STENNER 45M5 CHEMICAL PUMP WAS REPLACED WITH A PENTAIR RAINBOW 300-29X EROSION FEEDER. A STARITE S7M120 CARTRIDGE FILTER WAS REPLACED WITH A PENTAIR TRITTON II TR-100C FILTER. Correct By: 01-Jul-2021
3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical Outlet covers were not installed properly. screw holes were drilled into the covers and screws were installed in the wrong location
Do not operate the pool when the outlet covers are not installed.
REPLACE THE MAIN DRAIN COVERS AND INSTALL NEW ONES PROPERLY. Correct By: 22-Oct-2021
3701-31-04 (B)(4) / The licensee /authorized representative is keeping records
Repeat The licensee /authorized representative was not keeping or maintaining operational records.
All facility records must be maintained and available for review upon request.
TEST FREE CHORINE, TOTAL CHLORINE, AND pH BEFORE OPENING AND EVERY 4 HOURS. TEST WATER TEMPERATURE DAILY. TEST CYA AND ALK WEEKLY. Correct By: 23-Jun-2021
3701-31-04 (B)(4)(a)(vi) / Total alkalinity is tested weekly
Total alkalinity was not tested weekly.
Test total alkalinity at least once/week.
RECORD ALKALINITY WEEKLY. Correct By: 23-Jun-2021
3701-31-04 (B)(4)(a)(vii) / Cyanuric acid is tested weekly
Cyanuric acid was not tested weekly.
Test for cyanuric acid level at least once/week.
RECORD CYANURIC ACID WEEKLY. Correct By: 23-Jun-2021
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. Skimmer weirs missing.
All equipment must be maintained in accordance with the manufacturers specifications.
REPLACE THE MISSING WEIRS IN THE SKIMMERS.
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. Chlorinator leaking
All equipment must be maintained in accordance with the manufacturers specifications.
PLACE LID ON CHLORINATOR PROPERLY TO PREVENT LEAKING.
3701-31-04 (B)(6)(c)(i) / Backflow prevention devices shall be maintained.
Corrected During Inspection Backflow prevention devices were not maintained to function properly. The hose bib on the outside of the equipment room is not protected with an ASSE 1011 backflow preventer.
Have the backflow prevention device evaluated or replaced so that backflow is prevented.
INSTALL AN ASSE 1011 BACKFLOW PREVENTER ON THE HOSE BIB OUTSIDE OF THE EQUIPMENT ROOM.
3701-31-04 (B)(6)(c)(i) / Backflow prevention devices shall be maintained.
Backflow prevention devices were not maintained to function properly
Have the backflow prevention device evaluated or replaced so that backflow is prevented.
WATER IS FILLED AT A FILL SPOUT LOCATED IN THE EQUIPMENT ROOM. REPORTEDLY, THIS FILL SPOUT IS PLUGGED AND NO LONGER USED. AN DIRECT CONNECTION FROM THE MAIN WATER LINE HAS BEEN MADE TO THE POOL WITH A HOSE CONNECTION. AN ASSE 1015 BACKFLOW PREVENTER IS IN BETWEEN THE MAIN WATER LINE AND THE POOL. EITHER DISCONNECT THIS CONNECTION AND REMOVE THE HOSE AND HOSE BIB OR INSTALL AN ASSE 1013 BACKFLOW PREVENTER TO REPLACE THE ASSE 1015 BACKFLOW PREVENTER.
3701-31-04 (B)(6)(c)(ii) / Backwash lines and lines from drainage sumps shall have an air gap and remain open to freely drain.
Repeat Backwash lines and lines from drainage sumps did not have an air gap prior to discharge
Open the lines that discharge into the backwash or drainage sumps so that there is an air gap and the lines can drain freely.
PROVIDE AN AIR GAP ON THE BACKWASH LINE FROM THE FILTER TO THE SANITARY SEWER. THE EXISTING LINE CAN BE CUT AND THE LINE CAN BE BROUGHT UP AND OVER THE PUMP TO THE FLOOR DRAIN. Correct By: 01-Jul-2021
3701-31-04 (B)(6)(k) / Outlet drain covers are secure/meet ANSI/ASME A112.19.8-2007 requirements.
Critical Outlet covers did not meet ANSI/ASME A112.19.8-2007 standards. The certificate of compliance not available.
Meet the ANSI/ASME A112.19.8-2007 standard.
MAINTAIN THE CERTIFICATE OF COMPLIANCE FOR THE MAIN DRAIN COVERS. Correct By: 23-Jun-2021
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Ladders/stairs/steps were not in good repair or were not slip resistant. Hand rail loose
Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair.
TIGHTEN THE HANDRAIL. Correct By: 01-Jul-2021
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Gates or doors were not self-closing and lockable.
Repair gates or doors in order to be self-closing and lockable.
ADJUST GATE. Correct By: 23-Jun-2021
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Repeat pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
ADJUST THE pH. Correct By: 23-Jun-2021
3701-31-04 (D)(05) / Cyanuric acid level shall not exceed 70 ppm.
Repeat Cyanuric acid level exceeded 70 ppm
Drain the pool at least halfway and fill with clean water. Monitor the amount of cyanuric acid being used and adjust accordingly.
REDUCE CYA. Correct By: 24-Jun-2021
3701-31-04 (D)(8) / Acceptable test kit provided/adequate/in good repair
Acceptable test kit was not provided. Reagents have expired.
Obtain a test kit that can accurately indicate the water quality of the swimming pool.
OBTAIN A NEW TEST KIT WITH FRESH REAGENTS. Correct By: 01-Jul-2021
3701-31-04 (E)(2)(a)(ii) / A USCG Type IV personal flotation device with 30 -60 foot throw line provided
A USCG Type IV personal flotation device with 30 -60 foot throw line was not provided at the unguarded pool.
Provide a proper floatation device at all times.
KEEP RING BUOY VISIBLY OUT IN POOL AREA. Correct By: 23-Jun-2021
3701-31-04 (E)(2)(a)(iii) / A back/spine board is provided
A back/spine board without a head immobilizer and straps was not provided at the unguarded pool.
Provide the back/spine board at the pool at all times.
KEEP SPINE BOARD VISIBLY OUT IN POOL AREA. Correct By: 23-Jun-2021
3701-31-04 (E)(2)(b)(i) / 12 ft. non-telescopic reach pole with Sheppard's crook & a USCG Type IV personal flotation device with 30 - 60 foot throw line.
12 ft. non-telescopic reach pole Shepherd's crook was bent.
Provide the non-telescopic reach pole and personal floatation device at the pool at all times.
REPLACE THE SHEPHERD'S CROOK ON THE REACH POLE. THE EXISTING ONE IS DAMAGED. Correct By: 01-Jul-2021
3701-31-04 (E)(2)(d) / First aid kit provided
Repeat First aid equipment was not provided.
Provide first aid equipment, including a first aid kit, at the pool at all times.
KEEP FIRST AID KIT WHERE SWIMMERS CAN ACCESS IT. Correct By: 01-Jul-2021
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 22-June-2021
Comments |
---|
Our records show that the main drain suction outlet covers (Hayward WG1048E) were installed 5/1/2017. |