3701-31-04 (A) / Approval shall be obtained for any construction or alterations of a public swimming pool.
Equipment, at a public swimming pool, was changed/altered without obtaining approval from the Ohio Department of Health (ODH) by submitting an Equipment Replacement Notification (ERN).
Obtain approval from the Ohio Department of Health (ODH) by submitting an Equipment Replacement Notification (ERN) before operating pool.
SUBMIT AN ERN TO ODH FOR THE REPLACEMENT OF THE DISINFECTION CHEMICAL FEEDER. THE LMI MILTON ROY A151-92T WAS REPLACED WITH A LMI MILTON ROY 8D851-83351. Correct By: 16-Mar-2023
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications. Wier in skimmer missing.
All equipment must be maintained in accordance with the manufacturers specifications.
WEIR HAS BEEN ORDERED AND WILL BE INSTALLED UPON RECEIPT. Correct By: 30-Mar-2023
3701-31-04 (B)(6)(t) / Equipment/chemical/storage areas are free of hazards/accessible only to authorized personnel.
Critical Equipment/chemical/storage areas were not secured.
These storage areas must be kept inaccessible to everyone but authorized personnel. Secure the areas.
KEEP DOOR TO CHEMICAL STORAGE ROOM AND WOMEN'S SPA EQUIPMENT ROOM CLOSED AND LOCKED. Correct By: 09-Mar-2023
3701-31-04 (D)(7)(d) / Flow or pressure switch with a shut off valve shall be provided and tested monthly.
Critical Flow or pressure switch for a shut off valve was not tested monthly
Provide records indicating that the unit is being tested monthly.
TEST AND RECORD ON THE LOG SHEET THE ACC FLOW SWITCH FUNCTION MONTHLY. Correct By: 09-Mar-2023
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 09-March-2023
Comments |
---|
The Certificate of Compliance for the main drain covers is available. Our records show that the main drain suction outlet covers (Waterway 640-472xV) were installed 4/9/2019. The covers have a 7 year life span and must be replaced before 4/9/2026. These drain covers have a maximum flow rating of 356 gpm. When replacing the covers, ensure that the new covers' flow rating will not be exceeded. 450 gpm. The operator was observed performing onsite chemical tests appropriately and is aware of the acceptable parameters and necessary corrective actions. Keep the chemicals’ Safety Data Sheets (SDS) in the equipment room and have Personal Protective Equipment (PPE) such as chemical gloves and goggles available for handling chemicals. EMERGENCY PHONE WAS NOT TESTED AT THIS INSPECTION, BUT WILL BE IN THE FUTURE. |