3701-31-04 (B)(6)(q) / Depth markers/deck warning signs are maintained
Repeat Depth markers/deck warning signs were not maintained in a clearly legible/visible manner.
Replace the depth markers/deck warning signs so that bathers are able to clearly see the depth of the water and that no diving is permitted where clearly indicated.
PROVIDE ADDITIONAL DEPTH MARKINGS. THEY MUST BE NO MORE THAN 25 FT APART, AT LEAST 4 INCHES IN HEIGHT, AND NO MORE THAN 24 INCHES AWAY FROM THE EDGE OF THE WATER. Correct By: 17-Aug-2018
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Repeat Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm. Correct By: 04-Aug-2018
3701-31-04 (D)(7)(d) / Flow or pressure switch with a shut off valve shall be provided and tested monthly.
Critical Repeat Flow or pressure switch for a shut off valve was not tested monthly
Have the ACC unit serviced or replaced with a unit that has a flow or pressure switch with an automatic shut off valve. Provide records indicating that the unit is being tested monthly.
TEST AND RECORD THE ACC FUNCTION TEST MONTHLY. Correct By: 04-Aug-2018
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 27-July-2018
Comments |
---|
PROVIDE A SIGN THAT STATES "WARNING POOL CLOSED" OR "DANGER POOL CLOSED". |