3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
ORP reading was below 650 mv
Have the ACC unit inspected to determined why the ORP is low. Correct By: 06-Jul-2022
3701-31-04 (E)(2)(d) / First aid kit provided
First aid equipment was not provided.
Provide first aid equipment, including a first aid kit, at the pool at all times.
KEEP THE FIRST AID KIT OUT IN THE POOL AREA AVAILABLE TO SWIMMERS. Correct By: 06-Jul-2022
3701-31-04 (E)(3)(b) / "Children must be supervised" or "Swimming alone is not recommended" signs posted
The unguarded pool was in use without the "Children must be supervised" and/or "Swimming alone is not recommended" signs posted.
Post the "Children must be supervised" and/or "Swimming Alone is Not Recommended" signs at all times the pool is available for use.
POST SIGN STATING "SWIMMING ALONE IS NOT RECOMMENDED" Correct By: 06-Jul-2022
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 28-June-2022
Comments |
---|
HAVE THE BACKFLOW PREVENTER INSPECTED ANNUALLY AND HAVE DOCUMENTATION AVAILABLE FOR INSPECTION. When using CYA (cyanuric acid) the alkalinity level is calculated by subtracting 1/3 the CYA level from the alkalinity reading. EXAMPLE: alkalinity test reading = 70 ppm, CYA = 60 ppm. Alkalinity is 70 ppm – (60/3) = 50 ppm Keep the chemicals’ Safety Data Sheets (SDS) in the equipment room and have Personal Protective Equipment (PPE) such as chemical gloves and goggles available for handling chemicals. The Certificate of Compliance for the main drain cover(s) is/are available in the equipment room. Our records show that the main drain suction outlet covers (Lawson MLD-SG-1212) were installed 5-25-21. The covers have a 10 year life span and must be replaced before 5-25-31. |