3701-31-04 (D)(7)(d) / Flow or pressure switch with a shut off valve shall be provided and tested monthly.
Critical Flow or pressure switch for a shut off valve was not tested monthly
Have the ACC unit serviced or replaced with a unit that has a flow or pressure switch with an automatic shut off valve. Provide records indicating that the unit is being tested monthly.
TEST AND RECORD THE FUNCTION OF THE AUTOMATIC CHEMICAL CONTROLLER PRESSURE SWITCH. INSTALLATION OF SHUT OFF VALVES TO THE SENSORS MAY BE NEEDED. Correct By: 30-Nov-2018
Facility Type: Special Use
[?] Inspection Type: Standard
Inspection Date: 31-October-2018
Comments |
---|
DISCARD EXPIRED REAGENTS I WILL CHECK ON YOUR REQUIREMENT FOR: -POSTING A SIGN STATING "SWIMMING ALONE IS NOT RECOMMENDED" -POSTING A SIGN STATING "CHILDREN MUST BE SUPERVISED" -PROVIDING A 12 FT REACH POLE WITH A SHEPPARD'S CROOK |