3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
ORP reading was below 650 mv
Have the ACC unit inspected to determined why the ORP is low. Correct By: 15-Jun-2023
3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical Chlorine disinfectant residual was less than 1 ppm for the pool
Do not operate the pool when the disinfectant residuals are less than what is required. Ensure the chlorine disinfectant residual is at 1 ppm or above prior to placing the pool back into operation.
THIS IS A CRITICAL OPERATIONAL ITEM AND POSES AN IMMINENT HEALTH HAZARD. THE OPERATOR WAS INSTRUCTED TO TREAT THE POOL AND ENSURE THE FREE CHLORINE LEVEL IS AT LEAST 1 PPM BEFORE LETTING PEOPLE IN THE POOL. Correct By: 15-Jun-2023
3701-31-04 (B)(6)(n) / Proper pool operating water level is maintained
The operating water level of the pool was not maintained.
Decrease the volume of the pool water until the pool operating water level is restored.
LOWER WATER LEVEL SO SKIMMERS CAN OPERATE PROPERLY. Correct By: 21-Jun-2023
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 15-June-2023
Comments |
---|
Our records show that the main drain suction outlet covers (AquaStar A10RCFR) were installed 5/1/2021. The covers have a 5 year life span and must be replaced before 5/1/2026. The minimum required flow rate for a wading pool of this size is 56 gpm. The existing pump does not produce the required flow rate The floor inlets should should have a proper cover. |