3701-31-04 (A) / Approval shall be obtained for any construction or alterations of a public swimming pool.
Public swimming pool was constructed, installed, or substantially altered without obtaining approval from the Ohio Department of Health (ODH). Deck was resurfaced without approval.
Contact ODH to obtain approval for any construction/alterations before operating pool.
SUBMIT PLANS TO ODH FOR THE NEW DECK SURFACE. Correct By: 05-Aug-2020
3701-31-04 (B)(4)(a)(iv) / Water temperatures are recorded daily
Water temperatures were not being recorded daily.
Take and record the water temperature at least once/day. Correct By: 05-Aug-2020
3701-31-04 (B)(4)(a)(vi) / Total alkalinity is tested weekly
Total alkalinity was not tested weekly.
Test total alkalinity at least once/week. Correct By: 05-Aug-2020
3701-31-04 (B)(4)(c) / SVRS/APSOS/ACC test results/ service records are maintained
SVRS/APSOS/ACC test results/ service records were not maintained.
The test results/service records for these devices must be kept on site for review. If the device has not been recently serviced, have the device tested immediately and provide documentation of the test results.
TEST THE AUTOMATIC CHEMICAL CONTROLLER FLOW SWITCH/PUMP INTERLOCK MONTHLY. RECORD ON THE WEEKLY LOG SHEET. Correct By: 05-Aug-2020
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. Weirs are missing in the skimmers.
All equipment must be maintained in accordance with the manufacturers specifications.
REPLACE MISSING WEIRS IN THE SKIMMERS. Correct By: 05-Aug-2020
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
The gate did not close easily or self-close.
KEEP THE GATE CLOSED. REPAIR GATE SO THAT IT SELF-CLOSES. Correct By: 05-Aug-2020
3701-31-04 (D)(7) / Public spa shall have a functional automatic chemical controller
Critical The ACC is not functioning properly.
REPAIR THE ACC. Correct By: 05-Aug-2020
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 04-August-2020
Comments |
---|
VACUUM THE CORNERS OF THE POOL. |