3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications.
All equipment must be maintained in accordance with the manufacturers specifications. Correct By: 14-Jul-2014
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm. Correct By: 02-Jul-2014
3701-31-04 (D)( 6 )(a) / Spray ground free chlorine disinfectant residual is above 2 ppm.
Spray ground free chlorine disinfectant residual was below 2 ppm.
Do not operate the sprayground until the chlorine disinfectant is at 2 ppm or above.
3701-31-04 (D)(2) / Public swimming pool is continuously disinfected using a chemical feeding device connected to the circulation system
The pool was not being continuously disinfected using a chemical feeding device connected to the circulation system
Repair or replace the disinfection system so that the pool is continuously being disinfected. Correct By: 14-Jul-2014
Facility Type: Special Use
[?] Inspection Type: Standard
Inspection Date: 02-July-2014