[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(6)(p) / Deck surfaces are free of standing water or other hazards.
Repeat Deck surfaces had standing water or other hazards.
Repair areas of the deck where standing water is occurring. REPAIR THE DECK WHERE TRIPPING AND INJURY HAZARDS EXISTS.
3701-31-04 (D)(05) / Cyanuric acid level shall not exceed 70 ppm.
Repeat Cyanuric acid level exceeded 70 ppm
Drain the pool at least halfway and fill with clean water. Monitor the amount of cyanuric acid being used and adjust accordingly. REDUCE CYA TO BELOW 70 PPM Correct By: 10-Jul-2023


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 05-July-2023

Comments
POST THE CERTIFICATE OF COMPLIANCE FOR THE MAIN DRAIN COVERS.

When using CYA (cyanuric acid) the alkalinity level is calculated by subtracting 1/3 the CYA level from the alkalinity reading. EXAMPLE: alkalinity test reading = 70 ppm, CYA = 60 ppm. Alkalinity is 70 ppm – (60/3) = 50 ppm

The operator was observed performing onsite chemical tests appropriately

REPORTEDLY AN ERN HAS BEEN SUBMITTED TO ODH FOR THE CIRCULATION PUMP REPLACEMENT.