[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(1)(d) / Circulation/Disinfection system shall operate properly.
Critical Corrected During Inspection The pump was not running and there was no circulation.
THE PUMP MUST RUNNING CONTINUALLY. KEEP CLOSE WATCH ON THE PUMP. EXPLORE REASONS WHY THE PUMP KICKED OFF. Correct By: 29-Jun-2019
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. One skimmer was missing a basket and two were missing weirs.
All equipment must be maintained in accordance with the manufacturers specifications. PLACE A SKIMMER BASKET IN THE ONE MISSING A BASKET, AND REPLACE THE MISSING WEIRS IN THE TWO SKIMMERS MISSING WEIRS. Correct By: 06-Jul-2019
3701-31-04 (B)(6)(q) / Depth markers/deck warning signs are maintained
Repeat Depth markers/deck warning signs were not maintained in a clearly legible/visible manner.
Replace the depth markers/deck warning signs so that bathers are able to clearly see the depth of the water and that no diving is permitted where clearly indicated. PLACE AT LEAST 2 DEPTH MARKING AT THE ZERO ENTRY, EITHER "ZERO DEPTH" OR "O FT" OR "0 IN". MARKINGS MUST BE WITHIN 24 INCHES OF THE WATER AND AT LEAST 4 INCHES IN SIZE, AND NO MORE THAN 25 FT APART. Correct By: 06-Jul-2019
3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Repeat Chemical containers were stored without labels identifying the contents.
Label and properly store all chemical containers to avoid a chemical reaction or unnecessary exposure. PLACE A LABEL ON THE CHLORINE TANK. Correct By: 06-Jul-2019


Inspection Information


Facility Type: Special Use

[?] Inspection Type: Standard

Inspection Date: 28-June-2019

Comments
Our records show: The main drain suction outlet cover (AquaStar WAV 12) was installed 8/1/2018. The cover has a 5 year life span and must be replaced before 8/1/2023.

-THE FLOW METER APPEARS TO BE STUCK