3701-31-04 (A) / All construction or alterations of a public swimming pool are approved
Repeat Equipment has been replaced without submitting an ERN to ODH. The chemical disinfection pump has been replaced.
SUBMIT AN EQUIPMENT REPLACEMENT NOTIFICATION TO THE OHIO DEPARTMENT OF HEALTH. Correct By: 07-Mar-2018
3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical The main drain cover is missing 2 screws leaving the drain unsecured and in noncompliance with the manufacturer's instructions.
INSTALL THE MISSING SCREWS SUPPLIED BY THE MANUFACTURER INTO THE DRAIN COVER. Correct By: 07-Mar-2018
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. The Automatic Chemical Controller is not calibrated accurately.
All equipment must be maintained in accordance with the manufacturers specifications.
CALIBRATE THE AUTOMATIC CHEMICAL CONTROLLER SO THAT IT READS AND ADJUSTS CHEMICALS PROPERLY.
CLEAN THE PROBES AS INSTRUCTED BY THE MANUFACTURER. A TOOTHBRUSH AND TOOTHPASTE ARE COMMONLY USED. Correct By: 07-Mar-2018
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Repeat Ladders/stairs/steps were not in good repair or were not slip resistant. The bottom step is missing from the ladder closest to the pump room.
Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair.
REPLACE THE MISSING BOTTOM STEP ON THE LADDER BY THE FILTER ROOM. Correct By: 07-Mar-2018
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Repeat pH was outside the range of 7.2 to 7.8. The pH was 7.0
Treat the pool water so that the pH is within the acceptable range.
ADJUST THE pH TO BETWEEN 7.2 AND 7.8. Correct By: 01-Mar-2018
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Repeat Total alkalinity was less than 60 ppm. The alkalinity was 40 ppm.
Raise the total alkalinity to at least 60 ppm.
ADJUST THE ALKALINITY TO 60 PPM OR ABOVE. Correct By: 01-Mar-2018
3701-31-04 (E)(2)(d) / First aid kit provided
Repeat First aid equipment was not provided.
Provide first aid equipment, including a first aid kit, at the pool at all times.
IF THE KIT AID KIT IS HELD AT THE FRONT DESK, PLACE A SIGN IN THE POOL AREA INDICATING ITS LOCATION. Correct By: 07-Mar-2018
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 28-February-2018
Comments |
---|
TO AVOID ENFORCEMENT ACTION CORRECT THE VIOLATIONS STATED. |