3701-31-04 (B)(4)(a)(ii) / Combined chlorine is tested daily at pool side prior to use
Combined chlorine was not tested and recorded daily at pool side prior to use.
Test for combined chlorine prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use combined chlorine must be tested every 12 hours while the pool is in use.
3701-31-04 (B)(4)(a)(vi) / Total alkalinity is tested weekly
Total alkalinity was not tested and recorded weekly.
Test total alkalinity at least once/week and record.
3701-31-04 (B)(4)(a)(vii) / Cyanuric acid is tested weekly
Cyanuric acid was not tested and recorded weekly.
Test for cyanuric acid level at least once/week and record.
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications, Skimmer Weirs missing.
All equipment must be maintained in accordance with the manufacturers specifications, replace missing skimmer weirs.
3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Required turnover rates were not being met, flow needs to be minimum 111 gpm.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired.
3701-31-04 (E)(2)(d) / First aid kit provided
Repeat First aid equipment was not provided.
Provide first aid equipment, including a first aid kit, at the pool at all times.
3701-31-04 (E)(3)(a) / "WARNING, NO LIFEGUARD", sign posted
The unguarded pool was in use without the "WARNING, NO LIFEGUARD" sign posted.
Post the WARNING, NO LIFEGUARD sign in a conspicuos location at all times the pool is available for use.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 13-July-2017