3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Required turnover rates were not met.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve.
INCREASE THE FLOW RATE TO AT LEAST 57 GPM. Correct By: 06-Apr-2018
3701-31-04 (E)(3)(c) / Location of emergency telephone posted when the phone is not visible.
Repeat Sign indicating the location of the emergency device (telephone) was not provided and emergency device was not visible in the pool area. A sign stating the name and telephone number of emergency services is not posted.
Ensure that a sign informing patrons of the location of the emergency device is always visible in the pool area.
POST THE EMERGENCY NUMBERS BY THE PHONE. IF A "9" MUST BE DIALED FIRST POST CALL 9-911 IN CASE OF AN EMERGENCY. Correct By: 06-Apr-2018
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 05-April-2018