3701-31-04 (A) / All construction or alterations of a public swimming pool are approved
Repeat The disinfection feeder was replaced
SUBMIT ERN TO ODH FOR THE REPLACEMENT OF DISINFECTION FEEDER
3701-31-04 (B)(6)(i) / A means of determining rate-of-flow on all water pumps
Repeat A means of determining rate-of-flow was not found for all water pumps.
Properly install a flow meter or have a pump curve available for every water pump used for the pool.
POST THE PUMP CURVE FOR THE SPA JET PUMP AND THE CALCULATION FOR DETERMINING THE FLOW RATE.
3701-31-04 (D)(7)(d) / Flow or pressure switch with a shut off valve shall be provided and tested monthly.
Critical Repeat Flow or pressure switch for a shut off valve was not provided or the unit was not tested monthly
Have the ACC unit serviced or replaced with a unit that has a flow or pressure switch with an automatic shut off valve. Provide records indicating that the unit is being tested monthly.
RECORD TEST RESULTS OF THE ACC FLOW SWITCH FUNCTION
Facility Type: Spa
[?] Inspection Type: Standard
Inspection Date: 19-July-2019