[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (A) / All construction or alterations of a public swimming pool are approved
Repeat The disinfection feeder was replaced
SUBMIT ERN TO ODH FOR THE REPLACEMENT OF DISINFECTION FEEDER
3701-31-04 (B)(6)(i) / A means of determining rate-of-flow on all water pumps
Repeat A means of determining rate-of-flow was not found for all water pumps.
Properly install a flow meter or have a pump curve available for every water pump used for the pool. POST THE PUMP CURVE FOR THE SPA JET PUMP AND THE CALCULATION FOR DETERMINING THE FLOW RATE.
3701-31-04 (D)(7)(d) / Flow or pressure switch with a shut off valve shall be provided and tested monthly.
Critical Repeat Flow or pressure switch for a shut off valve was not provided or the unit was not tested monthly
Have the ACC unit serviced or replaced with a unit that has a flow or pressure switch with an automatic shut off valve. Provide records indicating that the unit is being tested monthly. RECORD TEST RESULTS OF THE ACC FLOW SWITCH FUNCTION