3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Required meters and gauges were not maintained or were not functional while the pool is in operation. THE FLOW METER IS READING 18 GPM AND THE MOTOR ON THE PUMP HAS BEEN CHANGED FROM A 1 hp TO A .75 HP. THE FLOW METER MAY NOT BE FUNCTIONING PROPERLY AND MAY NEED TO BE CLEANED OR REPLACED. THE FLOW RATE MAY INDEED BE LOW AND NEEDS TO BE INCREASED.
Maintain all meters and gauges in a properly functioning manner at all times while the pool is in operation.
EITHER REPAIR THE FLOW METER OR INCREASE THE FLOW RATE, AND/OR REPLACE THE MOTOR ON THE PUMP. Correct By: 08-Jul-2022
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
ADJUST pH Correct By: 04-Jul-2022
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm.
ADJUST ALKALINITY. Correct By: 04-Jul-2022
Facility Type: Spa
[?] Inspection Type: Standard
Inspection Date: 30-June-2022
Comments |
---|
THE 1 HP CIRCULATION MOTOR ON THE PUMP HAS BEEN REPLACED WITH A .75 HP MOTOR. APPROVAL MUST BE OBTAINED FROM THE OHIO DEPARTMENT OF HEALTH WHEN REPLACING A MOTOR IF THE REPLACEMENT CHANGES THE FLOW RATE BY MORE THAN 10%. ENSURE THAT THE FLOW METER IS OPERATING PROPERLY FIRST, THEN IF THE FLOW RATE IS NOT IN THE 40-50 GPM RANGE SUBMIT AN EQUIPMENT REPLACEMENT NOTIFICATION FORM TO ODH. The Certificate of Compliance for the main drain cover(s) is/are available in the equipment room. Our records show that the main drain suction outlet covers (AquaStar WAV12) were installed on 5/30/2019. The covers have a 5 yr lifespan and must be replaced before 5/30/2024. |