3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications. The flow reading was above the max allowable filter flow.
All equipment must be maintained in accordance with the manufacturers specifications.
REDUCE THE FLOW RATE TO 18 GPM OR LESS. IF THE FLOW METER IS NOT WORKING PROPERLY REPAIR FLOW METER. Correct By: 14-Jun-2019
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm.
ADJUST ALKALINITY. Correct By: 14-Jun-2019
3701-31-04 (D)(05) / Cyanuric acid level shall not exceed 70 ppm.
Repeat Cyanuric acid level exceeded 70 ppm
Drain the pool at least halfway and fill with clean water. Monitor the amount of cyanuric acid being used and adjust accordingly.
DRAIN PART OR ALL OF THE POOL TO REDUCE CYA TO 70 PPM OR LOWER. Correct By: 14-Jun-2019
Facility Type: Special Use
[?] Inspection Type: Standard
Inspection Date: 07-June-2019
Comments |
---|
Out records have been updated to show: The main drain suction outlet cover (AquaStar/Hayward WAV 12/WG1032B) was installed on 5-23-19. The cover has a 5/7 year life span and must be replaced before 5-23-24 and 5-23-26. -date mark the weekly operational log sheets. |