3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
ORP reading was below 650 mv
Have the ACC unit inspected to determined why the ORP is low.
3701-31-04 (B)(4)(a)(vi) / Total alkalinity is tested weekly
Total alkalinity was not tested weekly.
Test total alkalinity at least once/week.
TEST AN RECORD ALKALINITY WEEKLY ON THE LOG SHEETS. Correct By: 11-Jun-2021
3701-31-04 (B)(4)(c) / SVRS/APSOS/ACC test results/ service records are maintained
SVRS/APSOS/ACC test results/ service records were not maintained.
REPEAT VIOLATION - The test results/service records for these devices must be kept on site for review. If the device has not been recently serviced, have the device tested immediately and provide documentation of the test results.
TEST THE ACC FLOW SWITCH FUNCTION MONTHLY AND RECORD ON THE LOG SHEET. Correct By: 11-Jun-2021
3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Chemical containers were stored unsafely.
Properly store all chemical containers to avoid a chemical reaction or unnecessary exposure.
DO NOT STORE SODIUM BICARD ON TOP OF ACID OR DICHLOR. Correct By: 11-Jun-2021
3701-31-04 (E)(2)(b)(i) / 12 ft. non-telescopic reach pole with Sheppard's crook & a USCG Type IV personal flotation device with 30 - 60 foot throw line.
Corrected During Inspection 12 ft. non-telescopic reach pole with Shepherd's crook and a USCG Type IV personal flotation device with 30 - 60 foot throw line was not provided at the guarded pool.
Provide the non-telescopic reach pole and personal floatation device at the pool at all times.
KEEP REACH POLE WITH SHEPHERD'S CROOK AND RING BUOY OUT ON THE POOL AREA WHEN OPEN. Correct By: 11-Jun-2021
3701-31-04 (E)(2)(d) / First aid kit provided
First aid equipment was not complete. No disposable gloves available.
Provide first aid equipment, including a first aid kit, at the pool at all times.
PROVIDE GLOVES FOR THE FIRST AID KIT. Correct By: 11-Jun-2021
Facility Type: Special Use
[?] Inspection Type: Standard
Inspection Date: 10-June-2021
Comments |
---|
The Certificate of Compliance for the main drain cover is available in the equipment room. Our records show that the main drain suction outlet covers (AquaStar WAV 12) were installed 8/1/2018. The covers have a 5 year life span and must be replaced before 8/1/2023. The cover has a flow rating of 274 gpm. When replacing the covers, ensure that the new covers' flow rating will not be exceeded. 375 gpm. The operator was observed performing onsite chemical tests appropriately. THE TUBING FROM THE CHLORINE PUMP IS NOT RIGID. IT APPEARS THAT THE TUBING IS PINCHED REDUCING EFFECTIVENESS. |