3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Repeat The east gate was not self-closing and self-latching.
Repair gates or doors in order to be self-closing and lockable.
ADJUST THE EAST GATE SO THAT IT SELF-CLOSES AND SELF-LATCHES. Correct By: 19-Jun-2023
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 12-June-2023
Comments |
---|
When using CYA (cyanuric acid) the alkalinity level is calculated by subtracting 1/3 the CYA level from the alkalinity reading. EXAMPLE: alkalinity test reading = 70 ppm, CYA = 60 ppm. Alkalinity is 70 ppm – (60/3) = 50 ppm The Certificate of Compliance is not available for the main drain cover. Keep a copy at the facility for future review. Our records show that the main drain suction outlet covers (Hayward WG1048E) were installed 5/18/22. The covers have a 7 year life span and must be replaced before 5/18/29 Test reagnts should be used to test for alkalinity and cyanuric acid. |