3701-31-04 (A) / Approval shall be obtained for any construction or alterations of a public swimming pool.
Public swimming pool was constructed, installed, or substantially altered without obtaining approval from the Ohio Department of Health (ODH).
Contact ODH to obtain approval for any construction/alterations before operating pool.
HAVE NOT RECEIVED THE APPROVAL FROM ODH FOR THE CHLORINE PUMP REPLACEMENT YET.
3701-31-04 (B)(4)(c) / SVRS/APSOS/ACC test results/ service records are maintained
SVRS/APSOS/ACC test results/ service records were not maintained.
The test results/service records for these devices must be kept on site for review. If the device has not been recently serviced, have the device tested immediately and provide documentation of the test results.
TEST AND RECORD ON THE WEEKLY LOG THE ACC FLOW SWITCH AND SVRS. Correct By: 02-Jun-2022
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications. ACC cell valves broken.
All equipment must be maintained in accordance with the manufacturers specifications.
REPAIR THE VALVES ON THE TEST CELL TO THE ACC. Correct By: 03-Jun-2022
3701-31-04 (B)(6)(c) / Cross connection hazards shall be prevented.
Cross connection hazards were present. No air gap on fill line.
Remove all cross connection hazards from the pool area.
PROVIDE AN AIR GAP ON THE FILL LINE. BLACK HOSE MUST NOT BE INSIDE THE FILL STAND. Correct By: 03-Jun-2022
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Gates or doors were not self-latching.
Repair gates or doors in order to be self-latching.
REPAIR GATE LATCH.
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Perimeter barrier had gaps greater than 4 inches.
Repair the perimeter barrier so that there are not any gaps greater than 4 inches anywhere along the barrier.
REPAIR 2 HOLES IN THE FENCE TO THE EAST OF THE POOL IN THE OLD TENNIS COURT AND THE FENCE NOT ATTACHED TO THE POLE OR STRINGER ON THE WEST FACING FENCE IN THE OLD TENNIS COURT.
3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Chemical containers were stored without labels identifying the contents.
Label and properly store all chemical containers to avoid a chemical reaction or unnecessary exposure.
LABEL CHLORINE TANK. Correct By: 03-Jun-2022
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
ADJSUT pH. Correct By: 01-Jun-2022
Facility Type: Pool
[?] Inspection Type: Follow-up
Inspection Date: 01-June-2022
Comments |
---|
POOL STILL CLOUDY, BUT POOL CAN OPEN BECAUSE THE BOTTOM CAN BE SEEN. When using CYA (cyanuric acid) the alkalinity level is calculated by subtracting 1/3 the CYA level from the alkalinity reading. EXAMPLE: alkalinity test reading = 70 ppm, CYA = 60 ppm. Alkalinity is 70 ppm – (60/3) = 50 ppm Keep the chemicals’ Safety Data Sheets (SDS) in the equipment room and have Personal Protective Equipment (PPE) such as chemical gloves and goggles available for handling chemicals. The Certificate of Compliance for the main drain cover(s) is/are available in the equipment room. Our records show that the main drain suction outlet cover (AquaStar 8MF) was installed 8/5/2019. The cover has a 5 year life span and must be replaced before 8/5/2024. |