3701-31-04 (B)(4)(a)(i) / Disinfection residuals are tested daily at pool side at required intervals for pools/automatic chemical controllers/special features
Disinfection residuals were not tested daily at pool side and/or at the required intervals for pools/automatic chemical controllers/special features.
Observed chlroine was not recorded on 8/22-8/23/23.
Test the disinfection residual every day before bathers enter the water. Disinfection residual must then be tested every 4 hours when an ACC is not in use. If an ACC is in use the disinfectant residual must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the disinfectant residual must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use.
3701-31-04 (B)(4)(a)(ii) / Combined chlorine is tested daily at pool side prior to use
Combined chlorine was not tested daily at pool side prior to use.
Observed the combined chlorine was not recorded on 8/22-8/23/23.
Test for combined chlorine prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use combined chlorine must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the combined chlorine must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use.
3701-31-04 (B)(4)(a)(iii) / pH is tested daily at pool side at required intervals for pools/automatic chemical controllers/special features
pH was not tested daily at pool side and/or at required intervals for pools/automatic chemical controllers/special features.
-Observed the pH was not recorded on 8/22/23-8/23/23.
pH must be tested prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use pH must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the pH must be tested at 1 special feature every 6 hours the sprayground or spray feature is in use.
3701-31-04 (B)(4)(a)(iv) / Water temperatures are recorded daily
Water temperatures were not being recorded daily.
Observed the water temperature was no recorded on 8/22-8/23/23.
Take and record the water temperature at least once/day.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 23-August-2023
Comments |
---|
-The full inspection was not able to be completed, because a thunderstorm started during the inspection. The water quality, disinfectant levels, and the emergency phone were not able to be tested during the inspection. -Records were not maintained on 8/22-8/23. Ensure the water quality and disinfectant levels are being tested at the required frequencies. -Combined and total chlorine are still being mixed up on the records. Ensure the employee testing the water understands what the are testing and recording. |