3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical The equalizer lines from the skimmers are not VGB compliant.
COVER THE SKIMMER EQUALIZER LINE OUTLETS WITH A VGB COMPLIANT COVER OR PLUG THE OUTLET AT THE POOL WALL. Correct By: 30-Jun-2018
3701-31-04 (B)(6)(c)(i) / Backflow prevention devices are maintained
Backflow prevention devices were not inspected and tagged.
Have the backflow prevention device evaluated or replaced so that backflow is prevented.
HAVE THE ASSE 1013 BACK FLOW PREVENTER INSPECTED ANNUALLY AND PROVIDE DOCUMENTATION OF INSPECTION (SUCH AS A TAG ON THE UNIT). Correct By: 30-Jun-2018
3701-31-04 (B)(6)(c)(ii) / Backwash lines and lines from drainage sumps have an air gap and are open to freely drain
Backwash lines and lines from drainage sumps did not have an air gap prior to discharge
Open the lines that discharge into the backwash or drainage sumps so that there is an air gap and the lines can drain freely.
PROVIDE A PROPER AIR GAP ON THE DRAIN LINE FROM THE FILTER BACK WASH LINE. Correct By: 30-Jun-2018
3701-31-04 (B)(6)(p) / Deck surfaces are free of standing water or other hazards.
Deck surfaces had standing water or other hazards.
REPAIR THE DECK WHERE THE CONCRETE IS UNEVEN. Correct By: 19-Jul-2018
3701-31-04 (E)(2)(d) / First aid kit provided
First aid equipment had some items that where mold/water damaged.
REPLACE WATER DAMAGED ITEMS IN THE FIRST AID KIT. Correct By: 30-Jun-2018
3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Emergency numbers are not posted by the phone.
POST EMERGENCY NUMBERS BY THE PHONE. "CALL 9-1-1" Correct By: 30-Jun-2018
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 19-June-2018
Comments |
---|
IF THE RAINBOW 300-29X CHLORINATOR IS USED, ONLY USE TRI-CHLOR, NOT DI-CHLOR |