3701-31-04 (B)(4) / The licensee /authorized representative is keeping records
Repeat The licensee /authorized representative was not keeping or maintaining operational records. No records were found.
All facility records must be maintained and available for review upon request.
TEST AND RECORD FREE, COMBINE AND TOTAL CHLORINE AND pH EVERY 4 HOURS, WATER TEMPERATURE DAILY, CYANURIC ACID AND ALKALINITY WEEKLY, AND THE SVRS MONTHLY. Correct By: 07-Jul-2019
3701-31-04 (B)(6)(b) / Replacement pipe is rigid PVC or the equivalent
Repeat Replacement pipe was not rigid PVC or equivalent.
Replace the non rigid PVC pipe with the proper rigid PVC pipe for public swimming pools.
REPLACE THE RUBBER COUPLING WITH RIGID PVC ASTM F441M-99. Correct By: 07-Jul-2019
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Repeat Ladders/stairs/steps were not in good repair or were not slip resistant.
Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair.
TIGHTEN HAND RAIL. Correct By: 07-Jul-2019
3701-31-04 (B)(6)(p) / Deck surfaces are free of standing water or other hazards.
Deck surfaces had standing water or other hazards.
Repair areas of the deck where standing water is occurring. If more than 50% of the deck must be replaced, plans must be submitted to the Ohio Department of Health for review and approval.
LEVEL THE CONCRETE BY THE LADDER. Correct By: 07-Jul-2019
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
The latch on the gate is broken.
REPAIR THE LATCH ON THE GATE. Correct By: 07-Jul-2019
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Repeat pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
INCREASE pH TO 7.2 TO 7.8 Correct By: 07-Jul-2019
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Repeat Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm.
INCREASE ALKALINITY TO 60 PPM OR MORE Correct By: 07-Jul-2019
3701-31-04 (D)(8) / Acceptable test kit provided/adequate/in good repair
Repeat Test is not acceptable. No CYA, or Alk reagent, Cl2 is OTO
OBTAIN A DPD TEST KIT TO TEST ALL REQUIRED CHEMICALS Correct By: 07-Jul-2019
3701-31-04 (E)(2)(d) / First aid kit provided
First aid equipment was not provided.
Provide first aid equipment, including a first aid kit, at the pool at all times.
KEEP THE FIST ID KIT AT THE POOL AREA OR POST A SIGN THAT THE FIRST AID KIT IS AT THE FRONT DESK. Correct By: 07-Jul-2019
3701-31-04 (E)(3)(b) / "Children must be supervised" or "Swimming alone is not recommended" signs posted
The unguarded pool was in use without the "Children must be supervised" and/or "Swimming alone is not recommended" signs posted.
Post the "Children must be supervised" and/or "Swimming Alone is Not Recommended" signs at all times the pool is available for use.
ADD A SIGN THAT STATES "SWIMMING ALONE IS NOT RECOMMENDED" Correct By: 07-Jul-2019
3701-31-04 (E)(3)(d) / "WARNING or DANGER - POOL CLOSED" sign(s) posted-when the pool is closed
The pool was closed but the "WARNING or DANGER - POOL CLOSED" sign(s) were not posted.
Post the "WARNING or DANGER - POOL CLOSED" sign at all times the pool is not available for use.
ADD THE WORD "DANGER" TO THE POOL CLOSED SIGN Correct By: 07-Jul-2019
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 05-July-2019