3701-31-04 (B)(6)(p) / Deck surfaces are free of standing water or other hazards.
Deck surfaces had standing water.
-Observed an area on the deck near a floor drain on the south side of the pool that had standing water.
Repair areas of the deck where standing water is occuring. If more than 50% of the deck must be replaced, plans must be submitted to the Ohio Department of Health for review and approval.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8.
-Observed the pH to be 7.0.
TREAT THE POOL WATER SO THE pH IS WITHIN THE ACCEPTABLE RANGE.
Correct By: 09-Jun-2023
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm.
-Observed the alkalinity to be 40ppm.
RAISE THE TOTAL ALKALINITY TO BE AT LEAST 60 PPM.
Correct By: 09-Jun-2023
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 07-June-2023
Comments |
---|
Our records show that the main drain suction outlet cover, Paramount SDX2 was installed in May 2023. The cover has a 5 year life span and must be replaced before May 2028. |