3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical Outlet covers were not secured. Two screws are missing in each main drain cover. The two screws in place are rusty.
Do not operate the pool when the outlet covers are not secured. Secure the covers prior to the pool being placed back into operation.
INSTALL FOUR SCREWS IN EACH DRAIN COVER. REPLACE THE RUSTY SCREWS.USE ONLY SCREWS SUPPLIED BY THE MANUFACTURER. SCREWS SHOULD BE STAINLESS STEEL.
SUPPLY THE CERTIFICATE OF COMPLIANCE FOR THE DRAIN COVERS.
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Repeat Gates or doors were not self-closing and lockable.
Repair gates or doors in order to be self-closing and lockable.
ADJUST GATE SO THAT IT SELF-CLOSES CONSISTENTLY.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 06-July-2022
Comments |
---|
Corrections made since the 6-1-22 inspection -CYA recorded at least weekly -Weirs in skimmers float freely with water level -CYA level is acceptable (70 ppm or below) -ACC test is recorded at least monthly - |