3701-31-04 (B)(4) / The licensee /authorized representative is keeping records
The licensee /authorized representative was not recording water quality parameters as required by rule.
Read and record required water quality parameters per rule.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was 8.0 which is outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
3701-31-04 (D)(05) / Cyanuric acid level shall not exceed 70 ppm.
Cyanuric acid level wa not which exceeded 70 ppm
Drain the pool at least halfway and fill with clean water. Monitor the amount of cyanuric acid being used and adjust accordingly.
3701-31-04(D)(6)(a)(2) / Pool free chlorine disinfectant residual shall be above 1 ppm.
Critical Pool free chlorine disinfectant residual was 0 which is below the minimum 1 ppm.
Do not operate the pool until the chlorine disinfectant residual is at 1 ppm or above.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 25-August-2016