[?] A summary of the violations found during the inspection are listed below.

No critical violations were documented at the time of inspection.

No violations were documented at the time of inspection.


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 11-July-2023

Comments
The pool was observed to still be closed due to cloudiness and algae growth.

The pool had been shocked with dichlor, so the bromine levels were high at the time of inspection. Dichlor contains cyanuric acid, and that was observed to be 55ppm at the time of the inspection.

CDC DOES NOT RECOMMEND BROMINE LEVELS HIGHER THAN 8 PPM.

The main drain suction outlet cover (Hayward WG1048E) was installed 9-15-2016. The cover has a 7 yr lifespan and must be replaced by 9-15-2023. The skimmer equalizer line suction outlet cover (Aquastar 4HP) was installed 5-9-18. The cover has a 5 yr lifespan and expired on 5-9-23. Provide documentation of a new skimmer equalizer line suction outlet cover.