3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Required turnover rates were not met.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve.
INCREASE FLOW RATE TO AT LEAST 50 GPM.
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm.
ADJUST ALKALINITY. Correct By: 22-Jun-2023
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 16-June-2023
Comments |
---|
Chemical feeder pumps should not be mounted above other chemical feeder pumps or chemical containers to prevent possible mixing of chemicals and producing toxic gas. If chlorine is mixed with muriatic acid chlorine gas is formed, which can lead to severe injuries and fatalities (SIFs) to exposed individuals. Our records show that the main drain suction outlet covers (Aqua Star A10RDFR) were installed 5/12/21. The covers have a 5 year life span and must be replaced before 5/12/2026. The minimum required flow rate for a wading pool of this size is 50 gpm. The existing pump does not produce the required flow rate. |