3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical Repeat Outlet covers were not secured. Two Screws are missing in the main drains.
Do not operate the pool when the outlet covers are not secured. Secure the covers prior to the pool being placed back into operation.
INSTALL ALL 4 SCREWS IN THE MAIN DRAINS AS DIRECTED BY THE MANUFACTURER'S INSTRUCTIONS.
3701-31-04 (B)(4)(a)(vii) / Cyanuric acid is tested weekly
Repeat Cyanuric acid was not tested weekly.
Test for cyanuric acid level at least once/week.
TEST AND RECORD CYA WEEKLY ON THE LOG SHEET, Correct By: 06-Jun-2023
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Ladders/stairs/steps were not in good repair or were not slip resistant. Steps on the ladder are slippery.
Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair.
REPLACE THE MISSING TREAD ON THE LADDER STEPS. Correct By: 06-Jun-2023
3701-31-04 (D)(05) / Cyanuric acid level shall not exceed 70 ppm.
Cyanuric acid level exceeded 70 ppm
Drain the pool at least halfway and fill with clean water. Monitor the amount of cyanuric acid being used and adjust accordingly.
LOWER CYA. Correct By: 06-Jun-2023
3701-31-04 (E)(2)(d) / First aid kit provided
First aid equipment bandages are water stained..
Provide first aid equipment, including a first aid kit, at the pool at all times.
REPLACE THE BANDAGES IN THE FIRST AID KIT WITH STERILE FRESH BANDAGES. Correct By: 06-Jun-2023
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 30-May-2023
Comments |
---|
Keep documentation of the ASSE 1013 backflow preventer’s annual inspection available at the pool facility for review by the health department. When using CYA (cyanuric acid) the alkalinity level is calculated by subtracting 1/3 the CYA level from the alkalinity reading. EXAMPLE: alkalinity test reading = 70 ppm, CYA = 60 ppm. Alkalinity is 70 ppm – (60/3) = 50 ppm Our records show that the main drain suction outlet covers (Waterway 640-472xV) were installed on 6-1-21. The covers have a 7 year life span and must be replaced before 6-1-28. The main drain certificate of compliance is in the old binder. Be careful not to misplace it. The chemicals' MSDS are in a pile of old reports. Be care not to misplace them too. Check the flow meter. There may sand next to the float. Check the filter pressure gauge. It was reading 2 psi. The CDC does not recommend chlorine levels to exceed 10 ppm. |