3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
ORP reading was below 650 mv
Have the ACC unit inspected to determined why the ORP is low. Correct By: 21-Sep-2018
3701-31-04 (B)(4) / The licensee /authorized representative is keeping records
The licensee /authorized representative was not keeping or maintaining operational records. The free, combine, and total chlorine readings and not recorded.
All facility records must be maintained and available for review upon request.
TEST AND RECORD THREE CHLORINE READINGS, FREE, COMBINE, AND TOTAL CHLORINE. Correct By: 21-Sep-2018
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. The skimmer box is missing the weir.
All equipment must be maintained in accordance with the manufacturers specifications.
REPLACE THE WEIR IN THE SKIMMER. Correct By: 03-Oct-2018
3701-31-04 (D)(7)(d) / Flow or pressure switch with a shut off valve shall be provided and tested monthly.
Critical Flow or pressure switch for a shut off valve was not tested monthly
Have the ACC unit serviced or replaced with a unit that has a flow or pressure switch with an automatic shut off valve. Provide records indicating that the unit is being tested monthly.
TEST AND RECORD ACC FUNCTION MONTHLY Correct By: 21-Sep-2018
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 19-September-2018
Comments |
---|
Corrections that have been made since the last inspection dated 4-10-18 -handrail is tight -test reagents are fresh CONTINUE TO USE THE AQUA BLUE CHLORINE TABS AS REQUIRED BY MANUFACTURER |