3701-31-04 (B)(6)(t) / Equipment/chemical/storage areas are free of hazards/accessible only to authorized personnel.
Critical The equipment room was not locked.
THE EQUIPMENT AND CHEMICAL ROOMS MUST BE INACCESSIBLE. KEEP THE EQUIPMENT ROOM LOCKED. Correct By: 10-Jul-2020
3701-31-04 (D)(7)(d) / Flow or pressure switch with a shut off valve shall be provided and tested monthly.
Critical Repeat Flow or pressure switch for a shut off valve was not provided or the unit was not tested monthly
Have the ACC unit serviced or replaced with a unit that has a flow or pressure switch with an automatic shut off valve. Provide records indicating that the unit is being tested monthly.
RECORD THE ACC FUNCTION TEST ON THE LOG SHEET AT LEAST MONTHLY AND BEFORE OPENING.
RECORD THE DATES ON THE LOG SHEETS.
3701-31-04 (D)(8) / Acceptable test kit provided/adequate/in good repair
The test kit reagents were not stored properly.
STORE TEST REAGENTS ACCORDING TO MANUFACTURER'S INSTRUCTIONS. KEEP REAGENTS OUT OF THE LIGHT. Correct By: 15-Jul-2020
3701-31-04 (E)(2)(d) / First aid kit provided
First aid kit did not have gloves
Provide first aid equipment, including a first aid kit, at the pool at all times.
PROVIDE GLOVES FOR THE FIRST AID KIT. Correct By: 15-Jul-2020
3701-31-04 (E)(3)(d) / "WARNING or DANGER - POOL CLOSED" sign(s) posted-when the pool is closed
Repeat The pool was closed but the "WARNING or DANGER - POOL CLOSED" sign(s) were not posted.
Post the "WARNING or DANGER - POOL CLOSED" sign at all times the pool is not available for use.
ADD THE WORD "WARNING" OR "DANGER" TO YOUR POOL CLOSED SIGN. Correct By: 15-Jul-2020
Facility Type: Special Use
[?] Inspection Type: Standard
Inspection Date: 09-July-2020
Comments |
---|
-Keep the chemicals’ Safety Data Sheets (MSDS) in the equipment room and have Personal Protective Equipment (PPE) such as chemical gloves and goggles available for handling chemicals. -The Certificate of Compliance was not available for the main drain cover. One was supplied to operator at the time of inspection. Keep a copy at the facility for future review. -Our records show the main drain suction outlet cover (Lawson MLD SG 1212) was installed 9-3-18. The cover has a 10 year life span and must be replaced before 9-3-28. -The depth markings are wearing off. New depth markings may need to be repainted next year. - The 911 operator had the wrong address for the pool. Call the 911 operator to ensure they have the correct address. |