3701-31-04 (B)(1)(k) / Chemical storage or use shall not result in imminent health hazard.
Critical Repeat Different types of chemical are stored on top of each other.
DO NOT STORE DIFFERENT TYPE OF CHEMICALS ON TOP OF EACH OTHER. Correct By: 02-Oct-2017
3701-31-04 (B)(6)(b) / Replacement pipe is rigid PVC or the equivalent
Repeat Replacement pipe was not rigid PVC or equivalent. A rubber coupling is used before the pump.
Replace the non rigid PVC pipe with the proper rigid PVC pipe for public swimming pools.
REPLACE THE RUBBER COUPLING WITH APPROVED RIGID PIPE. Correct By: 02-Oct-2017
3701-31-04 (B)(6)(c)(ii) / Backwash lines and lines from drainage sumps shall have an air gap and remain open to freely drain.
Backwash lines and lines from drainage sumps did not have an air gap prior to discharge
Open the lines that discharge into the backwash or drainage sumps so that there is an air gap and the lines can drain freely.
PROVIDE AN AIR GAP ON THE BACKWASH LINE. Correct By: 02-Oct-2017
3701-31-04 (B)(6)(t) / Equipment/chemical/storage areas are free of hazards/accessible only to authorized personnel.
Critical Repeat The filter room with chemicals was not locked.
KEEP THE CHEMICAL/FILTER ROOM LOCKED. Correct By: 02-Oct-2017
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 02-October-2017