[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical The main drain covers are missing 2 screws making them noncompliant with the manufacturer's instructions.
INSTALL THE MANUFACTURER'S SUPPLIED SCREWS INTO THE MAIN DRAIN COVERS. Correct By: 07-Mar-2018
3701-31-04 (B)(1)(e) / Automatic Chemical Controller (ACC) shall function properly.
Critical Automatic Chemical Controller (ACC) was not functioning properly at the time of the inspection. The alarm light was not functioning.
Do not operate the pool when the ACC unit is not functioning properly. Ensure that the ACC unit is functioning properly prior to placing the pool back into operation. REPAIR THE ALARM LIGHT ON THE ACC. Correct By: 07-Mar-2018
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications. The flow rate exceeded the maximum flow allowable for commercial use of the filter.
All equipment must be maintained in accordance with the manufacturers specifications. REDUCE THE FLOW RATE TO BETWEEN 26 AND 50 GPM. Correct By: 07-Mar-2018
3701-31-04 (B)(6)(c) / Cross connection hazards shall be prevented.
Repeat Cross connection hazards were present. A hose is attached to the pool circulation system without a backflow preventer.
Remove all cross connection hazards from the pool area. INSTALL ASSE 1011 BACKFLOW PREVENTER ON THE HOSE BIB IN THE FILTER ROOM. Correct By: 07-Mar-2018
3701-31-04 (B)(6)(c)(i) / Backflow prevention devices are maintained
Repeat Backflow prevention devices were not maintained to function properly. The ASSE 1013 backflow preventer was not inspected in the last 12 months.
Have the backflow prevention device evaluated or replaced so that backflow is prevented. HAVE THE BACKFLOW PREVENTER ASSE 1013 INSPECTED AND TAGGED AS INSPECTED. Correct By: 07-Mar-2018
3701-31-04 (B)(6)(p) / Deck surfaces are free of standing water or other hazards.
Deck surfaces had standing water or other hazards.
Repair areas of the deck where standing water is occurring. REPAIR THE DECK DRAIN COVER AT THE LADDER. Correct By: 28-Mar-2018
3701-31-04 (B)(6)(q) / Depth markers/deck warning signs are maintained
Repeat Depth markers/deck warning signs were not maintained in a clearly legible/visible manner.
Replace the depth markers/deck warning signs so that bathers are able to clearly see the depth of the water and that no diving is permitted where clearly indicated. INSTALL THE "NO DIVING" SIGN BY THE LIFT CHAIR. Correct By: 07-Mar-2018
3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Repeat Chemical containers were stored without labels identifying the contents.
Label and properly store all chemical containers to avoid a chemical reaction or unnecessary exposure. LABEL THE ACID AND CHLORINE TANKS SO THEY CAN BE PLAINLY SEEN Correct By: 07-Mar-2018
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Repeat Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm. INCREASE THE ALKALINITY LEVEL TO 60 PPM OR MORE. Correct By: 01-Mar-2018
3701-31-04 (E)(2)(d) / First aid kit provided
First aid equipment was not provided.
Provide first aid equipment, including a first aid kit, at the pool at all times. IF FIRST AID KIT IS HELD AT THE FRONT DESK, POST A SIGN IN THE POOL AREA INDICATING ITS LOCATION. Correct By: 07-Mar-2018


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 28-February-2018

Comments
"WATER TESTING AND RECORD KEEPING", "CRITICAL OPERATIONAL ITEMS", AND CDC FECAL ACCIDENT RESPONSE HANDOUTS WERE SUPPLIED TO THE OPERATOR AND REVIEWED TO ENSURE THAT THE OPERATOR IS KNOWLEDGEABLE OF THE REQUIRED CHEMISTRY LEVELS, CRITICAL ITEMS WHERE THE POOL MUST CLOSE, AND HOW TO RESPOND TO A FECAL ACCIDENT. THE OPERATOR SEEMED AWARE OF THESE ITEMS.