3701-31-04 (A) / All construction or alterations of a public swimming pool are approved
Repeat An ERN has not been submitted for the replacement of the chlorinator and filter.
SUBMIT AN EQUIPMENT REPLACEMENT NOTIFICATION FOR THE REPLACEMENT OF THE FILTER AND CHLORINATOR. SUBMIT TO THE OHIO DEPARTMENT OF HEALTH
3701-31-04 (B)(4) / The licensee /authorized representative is keeping records
Repeat The licensee /authorized representative was not keeping or maintaining operational records. Total and combine chlorine were not recorded.
All facility records must be maintained and available for review upon request.
TEST AND RECORD FREE, COMBINE AND TOTAL CHLORINE
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. Weirs missing in skimmers
All equipment must be maintained in accordance with the manufacturers specifications.
REPLACE THE MISSING WEIRS IN THE SKIMMERS
3701-31-04 (B)(6)(c)(ii) / Backwash lines and lines from drainage sumps have an air gap and are open to freely drain
Repeat Backwash lines and lines from drainage sumps did not have an air gap prior to discharge
Open the lines that discharge into the backwash or drainage sumps so that there is an air gap and the lines can drain freely.
REWORK THE BACKWASH PIPE FROM THE FILTER SO THERE IS AN AIR GAP.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
INCREASE pH TO 7.2 TO 7.8. Correct By: 13-Jul-2019
3701-31-04 (E)(2)(d) / First aid kit provided
Repeat First aid equipment was not provided.
Provide first aid equipment, including a first aid kit, at the pool at all times.
MAKE FIRST AID KIT AVAILABLE AT POOL
3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Repeat Emergency device (telephone) was not working.
Ensure that the emergency device is functioning properly and rings to the emergency response authorities.
REPAIR EMERGENCY PHONE
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 11-July-2019
Comments |
---|
Corrections made since the 6-6-19 inspection -The equalizer outlets are plugged The deck is smooth/repaired -the alkalinity is in acceptable range -a rope is on the ring buoy POST SIGN THAT STATES "WARMING POOL CLOSED" WHEN THE POOL IS CLOSED |