3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical Corrected During Inspection Chlorine disinfectant residual was less than 1 ppm for the pool
Do not operate the pool when the disinfectant residuals are less than what is required. Ensure the chlorine disinfectant residual is at 1 ppm or above prior to placing the pool back into operation.
POOL OPERATOR HAND FED THE CHLORINE AT THE TIME OF INSPECTION AND THE FREE CHLORINE LEVEL WAS MEASURED AT 1.8 AFTER 20 MINUTES. Correct By: 12-Jul-2022
3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Required meters and gauges were not maintained or were not functional while the pool is in operation.
Maintain all meters and gauges in a properly functioning manner at all times while the pool is in operation.
REPAIR FLOW METER. Correct By: 19-Jul-2022
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Gates or doors were not self-closing and lockable.
Repair gates or doors in order to be self-closing and lockable.
ONE GATE WAS MODIFIED AND IT SELF CLOSES. ONE STILL NEEDS FURTHER MODIFICATION IN ORDER TO SELF-CLOSE.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 12-July-2022
Comments |
---|
ADJUST pH AS NEEDED AFTER CHLORINE MIXES. |