3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications. Two weirs were missing in the skimmer.
All equipment must be maintained in accordance with the manufacturers specifications.
REPLACE THE WEIRS IN THE TWO SKIMMERS MISSING THEM. Correct By: 01-Jul-2022
3701-31-04 (B)(6)(c) / Cross connection hazards shall be prevented.
Cross connection hazards were present
Remove all cross connection hazards from the pool area.
PLACE AN ASSE 1011 VACUUM BREAKER ON THE HOSE BIB LOCATED IN THE EQUIPMENT ROOM. Correct By: 01-Jul-2022
3701-31-04 (B)(6)(n) / Proper pool operating water level is maintained
The operating water level of the pool was not maintained.
Decrease the volume of the pool water until the pool operating water level is restored.
REDUCE WATER LEVEL TO THE MIDDLE OF THE SKIMMER. Correct By: 01-Jul-2022
3701-31-04 (B)(6)(t) / Equipment/chemical/storage areas are free of hazards/accessible only to authorized personnel.
Critical Equipment/chemical/storage areas were not secured.
These storage areas must be kept inaccessible to everyone but authorized personnel. Secure the areas.
KEEP EQUIPMENT ROOM LOCKED. Correct By: 25-Jun-2022
Facility Type: Special Use
[?] Inspection Type: Standard
Inspection Date: 24-June-2022
Comments |
---|
When using CYA (cyanuric acid) the alkalinity level is calculated by subtracting 1/3 the CYA level from the alkalinity reading. EXAMPLE: alkalinity test reading = 70 ppm, CYA = 60 ppm. Alkalinity is 70 ppm – (60/3) = 50 ppm Safety Data Sheets (SDS) are kept in the equipment room and Personal Protective Equipment (PPE), chemical gloves and goggles, are available for handling chemicals. The Certificate of Compliance for the main drain cover(s) is/are available in the equipment room. Our records show that the main drain suction outlet covers (AquaStar WAV 12) were installed 8/1/2018. The covers have a 5 year life span and must be replaced before 8/1/2023. The cover has a flow rating of 274 gpm. WHEN REPLACING THE COVERS, ENSURE THAT THE NEW COVERS' FLOW RATING WILL NOT EXCEEDED. 375 gpm. The operator was observed performing onsite chemical tests appropriately and is aware of the acceptable parameters and necessary corrective actions. |