3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Repeat pH was outside the range of 7.2 to 7.8.
-Observed the pH to be less than 7.0.
ADJUST pH IN THE POOL TO BE BETWEEN 7.2-7.8.
Treat the pool water so that the pH is within the acceptable range. Correct By: 17-Jul-2023
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Repeat Total alkalinity was less than 60 ppm.
-Observed the alkalinity to be 30ppm.
PROMPTLY ADJUST THE ALKALINITY IN THE WADING POOL.
Raise the total alkalinity to at least 60 ppm. Correct By: 17-Jul-2023
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 13-July-2023
Comments |
---|
-When reviewing the records for the wading pool, it was observed that an SVRS system is being tested, but LCPH does not have a SVRS system on file for this wading pool. -The operator is mixing up combined chlorine and total chlorine on the records. -Note the repeat violations for pH and alkalinity. Ensure water samples are being taken pool side to get an accurate reading. |