3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical 0 ppm free chlorine was in the pool.
This violation is a critical operational item and poses an imminent health hazard. THE POOL MUST CLOSE UNTIL AT LEAST 1 PPM FREE CHLORINE CAN BE MAINTAINED. Correct By: 09-Jul-2019
3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Required turnover rates were not met.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve.
INCREASE FLOW RATE TO AT LEAST 68 GPM. Correct By: 16-Jul-2019
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Repeat Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm.
INCREASE ALKALINITY TO AT LEAST 60 PPM Correct By: 10-Jul-2019
3701-31-04 (D)(7)(d) / Flow or pressure switch with a shut off valve shall be provided and tested monthly.
Critical Repeat Flow or pressure switch for a shut off valve was not provided or the unit was not tested monthly
Have the ACC unit serviced or replaced with a unit that has a flow or pressure switch with an automatic shut off valve. Provide records indicating that the unit is being tested monthly.
TEST ACC MONTHLY. RECORD Correct By: 10-Jul-2019
3701-31-04 (E)(2)(a)(ii) / A USCG Type IV personal flotation device with 30 -60 foot throw line provided
Repeat A USCG Type IV personal flotation device with 30 -60 foot throw line was not provided at the unguarded pool.
Provide a proper floatation device at all times.
MAKE AVAILABLE THE RING BUOY WITH 30 FT ROPE. Correct By: 09-Jul-2019
3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Repeat Emergency device (telephone) was not working.
Ensure that the emergency device is functioning properly and rings to the emergency response authorities.
REPAIR EMERGENCY PHONE SO THAT THE OPERATOR CAN HEAR THE CALLER. Correct By: 11-Jul-2019
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 09-July-2019