[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(3) / Staff is trained and knowledgeable
Staff was not trained or knowledgeable in pool operations.
Train staff in pool operations, operation of equipment, chemical storage, use and handling and appropriate emergency procedures. PROVIDE EDUCATION FOR THE NEW OPERATOR. Correct By: 29-Jul-2020
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. The skimmers were missing the weirs.
All equipment must be maintained in accordance with the manufacturers specifications. REPLACE THE WEIRS IN THE SKIMMERS. Correct By: 29-Jul-2020
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications.
All equipment must be maintained in accordance with the manufacturers specifications. REDUCE THE FLOW RATE TO LESS THAN THE MAX FLOW RATING OF THE DRAIN COVERS (123 GPM) OR REPLACE THE DRAIN COVERS WITH ONES THAT HAVE A HIGHER FLOW RATING. Correct By: 29-Jul-2020
3701-31-04 (B)(6)(c)(i) / Backflow prevention devices shall be maintained.
Backflow prevention devices were not maintained to function properly on the hose bibbs.
Have the backflow prevention device evaluated or replaced so that backflow is prevented. PLACE ASSE 1011 BACKFLOW PREVENTERS ON THE 2 HOSE BIBS IN THE EQUIPMENT ROOM AND THE ONE OUTSIDE THE EQUIPMENT ROOM. Correct By: 29-Jul-2020
3701-31-04 (B)(6)(q) / Depth markers/deck warning signs are maintained
Depth markers/deck warning signs were not maintained in a clearly legible/visible manner.
Replace the depth markers/deck warning signs so that bathers are able to clearly see the depth of the water and that no diving is permitted where clearly indicated. REPAINT THE DEPTH MARKINGS AND "NO DIVING" MARKINGS IN LETTERING AT LEAST 4 INCHES IN SIZE, NO MORE THAN 24 INCHES FROM THE EDGE OF THE POOL, NO MORE THAN 25 FEET APART. Correct By: 29-Jul-2020
3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Corrected During Inspection Chemical container was stored without lid.
Label and properly store all chemical containers to avoid a chemical reaction or unnecessary exposure. KEEP LID ON CHEMICAL BUCKETS Correct By: 22-Jul-2020
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range. ADJUST THE pH. Correct By: 29-Jul-2020


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 22-July-2020

Comments
Pool was not yet open for the season.

Keep the chemicals’ Safety Data Sheets (MSDS) in the equipment room and have Personal Protective Equipment (PPE) such as chemical gloves and goggles available for handling chemicals.

The Certificate of Compliance was not available for the main drain cover. One was supplied to operator at the time of inspection. Keep a copy at the facility for future review.

The main drain suction outlet cover (New Water Solutions DS 360) was installed 7/5/2017. The cover has a 5 year life span and must be replaced before 7/5/2022. The cover has a flow rating of 123 gpm.

Pool operator training websites:

https://premierpoolmanagement.com/pages/cpo-100-online-information-options

https://www.aquaticcouncil.com/poolspa-operator-training/cpo-certified-pool-operator-online-course/?gclid=EAIaIQobChMIk66AxOHh6gIVAtvACh0KswDcEAAYAiAAEgIGzvD_BwE

https://bestaquatic.com/