3701-31-04 (B)(4)(a)(vi) / Total alkalinity is tested weekly
Total alkalinity was not tested weekly.
Test total alkalinity at least once/week. Correct By: 21-Jun-2018
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications. Skimmers and missing weirs and one is missing a basket
All equipment must be maintained in accordance with the manufacturers specifications.
REPLACE THE MISSING BASKET AND WEIRS IN THE SKIMMERS. Correct By: 30-Jun-2018
3701-31-04 (B)(6)(c)(i) / Backflow prevention devices are maintained
Backflow prevention devices were not inspected
Have the backflow prevention device evaluated or replaced so that backflow is prevented.
HAVE THE ASSE 1013 BACKFLOW PREVENTER INSPECTED ANNUALLY AND PROVIDE DOCUMENTATION OF INSPECTION. Correct By: 20-Jul-2018
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Repeat There is a gap between the bottom of the fence and the fence bottom rail that is more than 4".
ADJUST THE FENCE OR GROUND UNDER THE FENCE TO LIMIT TO GAP BELOW THE FENCE TO LESS THAN 4 INCHES. Correct By: 20-Jul-2018
3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Chemical containers were stored without labels identifying the contents.
Label and properly store all chemical containers to avoid a chemical reaction or unnecessary exposure.
LABEL THE CHLORINE TANK, STORE THE BAG OF SODIUM BICARB OFF OF THE FLOOR, AND DO NOT STACK DIFFERENT CHEMICALS ON TOP OF EACH OTHER. Correct By: 20-Jun-2018
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 20-June-2018
Comments |
---|
PROVIDE THE CERTIFICATE OF COMPLIANCE FOR THE MAIN DRAIN AND THE DATE OF INSTALLATION. |