Inspection Information | Facility Name: | Kozy Kampground Swimming Pool |
---|---|
Facility Type: | Pool |
[?] Inspection type: | Standard |
Inspection date: | 28-May-2021 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(6)(i) A means of determining rate-of-flow was not found for all water pumps. Properly install a flow meter or have a pump curve available for every water pump used for the pool. |
3701-31-04 (B)(6)(j) Critical Repeat SVRS device has not been tested recently. Please look into the steps involved with performing this test and then test at least monthly. Note: There is an unblockable drain cover on the main drain. Have the SVRS device tested and maintain the test results on site. |
3701-31-04 (B)(6)(s) Gates did not always self-close. Repair gates or doors in order to be self-closing and lockable. |
3701-31-04 (C)(2) pH was outside the range of 7.2 to 7.8. Treat the pool water so that the pH is within the acceptable range. |
Comments |
---|
The flow meter had broken while in the process of replacing. Another one will be installed. The gate didn't always close by itself. Check into testing the Vac-Alert monthly, at least. |