Facility Name: Pirate's Club Condos Swimming Pool
Facility Type: Pool
[?] Inspection type: Standard
Inspection date: 01-June-2018
Violations: A summary of the violations found during the inspection are listed below.
3701-31-04 (B)(6)(h)
Required meters and gauges were not maintained or were not functional while the pool is in operation. (Flow meter)
Maintain all meters and gauges in a properly funtioning manner at all times while the pool is in operation.
3701-31-04 (E)(2)(a)(ii)
A USCG Type IV personal flotation device with 30 -60 foot throw line was not provided at the unguarded pool.
Provide a proper floatation device at all times - that is accessible to all patrons - without having to unlock a storage room.
3701-31-04(D)(6)(a)(2)
Critical Pool free chlorine disinfectant residual was below 1 ppm.
Do not operate the pool until the chlorine disinfectant residual is at 1 ppm or above.
Comments
Please make sure you have the following safety items: spine board, ring buoy with rope, first aid kit. (I'm assuming there is a first aid kit in the restroom - I remember there being one in there in the past, but just make sure.) The ring buoy definitely needs to be out by the pool-side, similar to the shepherd's hook.

Flow meter was not working properly.... It should be measuring a flow of at least 70 gpm. Sometimes the tube inside the meter gets particles in it and the bobber gets lodged.