Inspection Information | Facility Name: | Romer's Westlake Villas |
---|---|
Facility Type: | Pool |
[?] Inspection type: | Standard |
Inspection date: | 15-July-2016 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(6)(h) Required meters and gauges were not maintained or were not functional while the pool is in operation. Found the flow meter "bobber" to be lodged, and therefore not functional. Maintain all meters and gauges in a properly funtioning manner at all times while the pool is in operation. Correct By: 16-Jul-2016 |
3701-31-04 (B)(6)(o) The handrail at the west end of the pool was loose. Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair. Correct By: 22-Jul-2016 |
3701-31-04 (C)(3) Total alkalinity was less than 60 ppm. Raise the total alkalinity to at least 60 ppm. Correct By: 16-Jul-2016 |