Inspection Information | Facility Name: | YMCA Piqua Branch-Male Spa |
---|---|
Facility Type: | Spa |
[?] Inspection type: | Follow-up |
Inspection date: | 05-May-2023 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (C)(7) Repeat At time of reinspection, observed spa water temperature at 104.5 F. Ensure spa water temperature is maintained less than 104.0 F. |
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04(D)(6)(a)(1)/Combined chlorine shall not exceed 1.0 ppm. Combined chlorine was greater than 1.0 ppm (2.2 ppm). Treat the pool so that the combined chlorine is less than 1 ppm. |
Comments |
---|
A time of reinspection, observed combined chlorine levels <1.0 and free chlorine >2.0. Alkalinity was tested and observed at 60 ppm. |